挂壁空调出风口滴水原因-如何解决出风口滴水问题

放大字体  缩小字体 发布日期:2017-11-24 17:24:17
导读: I believe many people have encountered such a problem, the air conditioning used for a long time after the outlet bega
  I believe many people have encountered such a problem, the air conditioning used for a long time after the outlet began to drip, and dripping more, then how to solve the air conditioning outlet drip problem? The next home grid to teach you how to solve the problem of hanging air-conditioning outlet drip.
How to solve the problem of outlet drip - observe the source of drip
Air supply system
Such as the filter dirty block, the use of low-humidity damp air file, if the air volume is too small, the lower the evaporator temperature, evaporator frost or even freeze, over time lead to leakage.
Drainage system
Mainly including the machine before and after the guide trough, drain, pipe banding, drainage pump failure, etc., when the air conditioning for a long time, the aqueducts, drains may be blocked by dirt leakage, aqueduct and other reasons for injection molding cracks, connecting pipe Joints include poor, drainage pipes are compressed when installed will cause leakage.
3. System lack of fluoride, the evaporator half blocked
System serious lack of fluoride, the refrigerant quickly into the evaporator near the input pipe 2-3 long U tube gasification, so the evaporator near the input pipe 2-3 root length U tube fin temperature Low, while the other long U-tube fin temperature close to room temperature, so close to the input tube 2-3 root long U tube fins will condense a large number of condensate, a long time will freeze. In the case of semi-clogged evaporator, the temperature of the long U-tube fin with a large amount of snow flow is low while the temperature of the long U-tube fin with a small flow rate of the snow is high, resulting in a large temperature difference between the two flow paths. So that a large flow of snow long U tube fins condense a large amount of condensate, and blown out, and the other due to hot and cold air in the duct intersection, water vapor condensation in the duct, leading to water leakage.
4. Installation problems lead to water leakage
Mainly concentrated in the new installed, or air-conditioning installed in winter, because the installation is not horizontal or drain pipe fittings are not bandaged.

相信许多人都遇到这样的问题,空调使用久了以后出风口开始滴水,而且越滴越多,那么应当怎么解决空调出风口滴水问题呢?接下来家电网就教您如何解决挂机空调出风口滴水问题。

如何解决出风口滴水问题-观察所滴水的来源

1.送风系统

如过滤网脏堵,潮湿环境下使用低风档,风量如果偏小,内机蒸发温度降低,蒸发器结霜甚至结冰,时间一长导致漏水。

2.排水系统

主要包括内机前后导水槽、排水管、管道包扎、排水泵故障等,当空调使用长时间后,导水槽、排水管都可能被脏物堵塞漏水,导水槽等因注塑原因有裂缝、连接管接头处包括不好,排水管安装时被压扁都会引起漏水。

3.系统缺氟、蒸发器半堵

系统严重缺氟的情况下,冷媒在进入蒸发器时很快在靠近输入管的2-3根长U管中气化,所以蒸发器靠近输入管的2-3根长U管翅片温度较低,而其他长U管翅片温度接近室温,故靠近输入管的2-3根长U管翅片上会凝结大量凝结水,时间长还会结冰。在蒸发器半堵的情况下,雪种流量较大的长U管翅片温度偏低而雪种流量较小的长U管翅片温度较高,致使两个流路间温差较大,而使雪种流量较大的长U管翅片凝结大量冷凝水,并随风吹出,另因冷热空气在风道内交汇,水蒸气在风道内凝结,最后导致漏水。

4.安装问题导致漏水

主要集中在新装机上,或是冬季安装的空调,因安装不水平或排水管、连接管接头未包扎好。

222222222.jpg

挂机空调出风口

如何解决空调出风口滴水问题-解决空调出风口问题的措施

1.新水平调整固定挂墙板角度

挂壁式内机安装不水平,常见原因为内机左低右高。

2.重新打孔(或扩孔修整)调整穿墙孔角度,达到内高外低

滴水原因为挂壁式室内机连接管出墙孔内低外高。

3.提高挂墙板高度 

挂壁式室内机排水口位置低于穿墙孔位置,造成冷凝水不能流出。

4.清除接水盘,使排水孔通畅

滴水原因为冷凝水盘积灰太多,排水孔堵塞。

5.检查排水管,有损坏时更新

滴水原因为冷凝水排水管折弯或压扁。

以上为家电网(www.020883.com)为您总结的常见空调出风口滴水问题的解决方法,通常大部分挂机空调出风口滴水问题都是由于安装位置不当所导致的,这时您只需要按照以上方法找出滴水原因就能够及时解决问题。