家电工程网 » 空调 » 空调原理 » 正文

空调漏氟原因分析及解决方法

放大字体  缩小字体 发布日期:2017-12-04 10:51:15
导读:  Leak fluorine is one of the common failure of air conditioning, leakage of fluorine, air-conditioning cooling and he
   Leak fluorine is one of the common failure of air conditioning, leakage of fluorine, air-conditioning cooling and heating efficiency will be greatly reduced, the air flow less. What is the cause of air leakage fluoride leak, the face of air conditioning leak fluorine users should do something to remedy it? This article home network Xiaobian detailed answers for you, hoping to reduce the user's use of air conditioners in trouble.

  漏氟是空调常见的故障之一,漏氟之后,空调的制冷制热效率会大大降低,出风量少之又少。那空调漏氟是什么原因造成的,面对空调漏氟用户应该做些什么进行补救呢?本文家电网小编将为您详细解答,希望减少用户在空调的使用中的烦恼。

空调问题.jpg

空调漏氟是什么原因造成的-喇叭口制作不良

Fluoride leakage reasons: 1, the flare edge overlap; 2, flared cutting pipe before the occurrence of deflection; 3, uneven connection pipe wall thickness caused by the bell mouth is not uniform; 4, bell mouth size is too small or too small Large; 5, the inner wall with chips, burrs; 6, a bell mouth cracks; 7, bell mouth scratches the wall.

Measures: In strict accordance with the requirements of flaring process making trumpet, so that the surface of the trumpet smooth, uniform periphery; the connection pipe to be straight, non-unqualified curved connection pipe is not for expansion bell.

What is the cause of leakage of fluorine air-conditioning - pipe joints are not coated with frozen oil

Fluoride leakage causes: Installation or maintenance, air-conditioning indoor and outdoor connection nozzle is not coated with frozen oil; or pipe fixed seal, resulting in air-conditioning leak fluorine.

Disposal measures: The frozen oil evenly coated joints inside and outside the connector, adjust the location of the pipeline, tighten the indoor and outdoor air-conditioning connection pipe leakage of fluoride copper cap, according to the installation process quantitative additional leak detection.

Leakage of air conditioning is what caused the reason - the bell mouth and the closure of the valve surface is not installed

Fluoride leakage reasons: the bell mouth and the valve or the end of the evaporator junction, the connection before the fixed, or the connection is too large, resulting in uneven fastening.

Action: The bell will be fixed in the hands of the middle position, while the fixed nut, to ensure that fixed in place.

What is the cause of leakage of fluorine air-conditioning - pipeline failure

Fluorine leakage reasons: indoor and outdoor air-conditioning pipe connection pipe, the pipe bending angle is too small, can lead to pipe leaks leak fluoride or fluorine-free.

Measures: air-conditioning indoors and outside the machine when connecting the pipe, the pipe bending radius to increase the appropriate amount to prevent pipe bending; corresponding leakage of fluorine pipe should be repaired or replaced in a timely manner.

What is the cause of leakage of fluoride air conditioning - refrigeration system has leaks

Leak fluorine reasons: In the replacement of refrigeration system components, the second part of the installation is not tight, there will be pipeline and refrigeration system leakage fluorine point.

Action: The soap is not too thick in the whole system of refrigeration piping, welded joints of the site for leak detection. Test conditions require refrigeration system nitrogen or fluorine filling, pay attention to carefully check the oil pipeline, followed by detection of leaks, according to the actual situation of parts repair or replacement.

These are the common causes of air leaks fluorine leak and solutions, in daily life, regular cleaning and repair air conditioning system, can well avoid air leakage of fluoride phenomenon. If the phenomenon of leakage of air leakage once the air conditioning, the owner should promptly contact with the professional air-conditioning engineering company, timely fluoride, to ensure the efficiency of air-conditioning.


漏氟原因:
1喇叭口边沿重叠2扩口前切割连接管出现偏斜3连接管壁厚不均造成喇叭口制作壁厚不均匀4喇叭口制作尺寸过小或过大5内壁有切屑毛刺6喇叭口有裂口7喇叭口内壁划伤。

处理措施:严格按照扩口工艺的要求制作喇叭口,使其喇叭口的表面光滑,周边均匀;连接管需平直,严禁选用未整理的弯曲不平连接管进行扩制喇叭口。

空调漏氟是什么原因造成的-管接头处未涂冷冻油

漏氟原因:安装或维修时,空调室内外机连接管口处未涂冷冻油;或管道固定密封不良,造成空调漏氟。

处理措施:将冷冻油均匀涂在连接管内外接头处,调整好管路的位置,紧固空调室内外机连接管的漏氟出铜帽,按安装工艺定量追加检漏

空调漏氟是什么原因造成的-喇叭口与截止阀面安装不到位

漏氟原因:喇叭口与截止阀面或内机蒸发器接头处,在连接前进行固定,或连接偏移过大,造成紧固不均匀。

处理措施用手将喇叭口固定在接头正中位置,同时固定螺帽,保证固定到位。

空调漏氟是什么原因造成的-管路故障

漏氟原因:空调室内外机连接管布管时,管路弯曲角度太小,也会致使管道弯裂漏氟或无氟。

处理措施:在空调室内外机连接管布管时,将管路弯曲半径适量加大,防止管道弯死;对应漏氟的管道应及时进行补焊或更换。

空调漏氟是什么原因造成的-制冷系统有漏点

漏氟原因:在更换制冷系统零件时,零件的二次安装不严密,会使管路及制冷系统存在漏氟点。

处理措施:将不太浓的肥皂水涂整机制冷系统管路、有焊接点的部位进行检漏。检测条件要求制冷系统充氮或充氟,注意仔细检查管路油污处依次查出漏点,根据实际情况进行零件维修或更换

以上是空调漏氟常见的几大原因及解决方法,在日常生活中,定期的清洗和检修空调系统,能很好地避免空调漏氟现象。如果一旦出现空调漏氟现象,业主应及时跟专业的空调工程公司(15907538990)取得联系,及时加氟,保证空调的使用效率。 

为您推荐更多相关文章